WAR NING:
Please refer to the System Installation Manual for information on limitations regarding product use and function, and information on the limitations as to liability of the manufacturer.
These instructions are to be used in conjunction with the appropriate Control Panel Installation Manual, with which this equipment is intended to be used.
This Installation Sheet applies to the following models: WT5500-433 / WT5500-868 / WT5500P-433 / WT5500P-868.
Operating Instructions shall be made available to the user.
Do not dispose the waste battery as unsorted municipal waste. Consult your local rules and /or laws regarding recycling of this battery, it will help protect the environment by reducing the number of batteries
consumed. Some of the materials that are found within the battery could become toxic if not disposed properly and/or may affect the environment, and indirectly everybody’s health.
WT5500 Installation Instructions
1
23
4
5
6
7
8
0
#
9
*
System is
Ready to Arm
<>
Function
Keys
LED Indicators
Ready
Armed
Trouble
AC Power
Scroll Keys
Ambient Light
Sensor
LCD
Emergency Keys
Fire
Auxiliary
Panic
< > indicates user can
scroll through options
DG009033
29007335R001
Enrolling the Keypad
The WT5500 must be configured in tandem with the PC9155 in order for the
system to function as desired.
1. Turn on the PC9155. The panel will be alert to any keypad enrollment
activity for a period of two minutes. Note that the PC9155 Ready and AC
LEDs will be flashing for this two-minute period.
2. A WT5500 must be turned on during this two-minute period for it to be
assigned to the PC9155.
3. Simultaneously press and hold [
] and [1]; by doing so you force the key-
pad to broadcast its ESN (Electronic Serial Number).
4. When the keypad has been successfully enrolled - this should take less
than 5 seconds - on the system, the message ‘Enrollment Successful’ will
be displayed on the keypad LCD for five seconds. The Ready and AC LEDs
will return to their previous state.
5. Repeat steps 3 and 4 on each additional keypad to be enrolled.
Programming Labels
1. Use this section to assign a meaningful name (e.g. Front Door, Hall-
way, etc.) to each zone.
2. Enter keypad programming by pressing
[][8][Installer Code][].
Enter the 3-digit section number for the label to be programmed.
3. Use the arrow keys (<>) to move the cursor underneath the letter to
be changed.
4. Press the number keys 1 through 9, corresponding to the letter you require.
For example, pressing number key 2 once will display the letter D; pressing
it again will display the letter E; pressing it a third time will display the let-
ter F, and so on.
5. When the required letter or number is displayed use the arrow keys (<>)
to scroll to the next letter.
6. When you are finished programming the Zone Label, press [
]. Scroll to
‘Save’ and press [] again.
7. Repeat Steps 2 through 5 until all Labels are programmed.
ASCII Characters
Broadcasting LCD Labels
LCD programming is done using the keypad. If more than one LCD keypad is
present on the system, labels programmed at one keypad can be broadcast
to all other LCD keypads. Perform the following in order to broadcast labels:
1. Program one LCD keypad completely.
2. Enter keypad programming by pressing [
][8][Installer Code][] at the
keypad that was programmed.
3. Enter Section [998]. The keypad will broadcast the label programming to
the PC9155. The PC9155 will then broadcast the label information to other
WT5500 keypads that have been enrolled by way of 2-way wireless.
NOTE: This operation may take several minutes.
4. When the keypad is finished press the [#] key to exit.
NOTE: Label broadcast from this keypad is only compatible with
other WT5500 keypads.
Changing Brightness/Contrast
1. Press [][6] [Master Code].
2. Use the arrow keys (<>) to scroll to Brightness or Contrast Control.
3. Press [
] to select the setting you want to adjust.
4. Brightness Control: There are multiple backlight levels. Use the arrow keys
(<>) to scroll to the desired level. Press [] to select.
5. Contrast Control: There are four different display contrast levels. Use the arrow
keys (<>) to scroll to the desired contrast level. Press [
] to select.
6. To exit, press [#].
NOTE: During battery operation, the keypad uses the ambient light
sensor to automatically adjust the backlighting brightness lev-
els in order to conserve battery life.
Changing the Buzzer Level
1. Press [][6] [Master Code].
2. Use the arrow keys (<>) to scroll to Buzzer Control. Press [
] to select.
3. Use the arrow keys (<>) to scroll to the desired buzzer level among
the 21 available selections. Press [
] to select.
4. To exit, press [#].
Keypad LED Symbols
Proximity Tags (WT5500P only)
You can use the proximity tag to perform any keypad function that would
normally require a user access code. Simply present the tag to the target icon
or to the left of the Keypad LCD.
Enrolling proximity tags
Enrolling a tag with one keypad will enroll it automatically to all WT5500P
keypads enrolled on the system.
1. Enter [][5][Master Code]. You will enter the
User Code Edit Select
menu.
2. Enter a two-digit User Code slot (01-16, 40) to be associated with the
proximity tag. Alternatively, scroll to the two-digit user number and press
the [
] key. You will enter the
New Code Edit
menu.
3. Enter the four- or six-digit New Code. The LCD will prompt you to swipe
your proximity tag. Otherwise, press the [#] key to exit.
4. Present your proximity tag to the keypad. If enrollment is successful,
acknowledgement beeps will sound and the keypad LCD will read ‘Tag
Enrolled Successfully’. If the proximity tag has been enrolled previously, an
error tone will sound. The LCD will read ‘Duplicate Tag/User Code’.
5. The keypad will return to the
User Code Edit Select
menu.
Deleting proximity tags
Delete the prox tags from the system when they are lost or no longer needed.
1. Enter [][5] [Master Code] on the keypad.
2. Enter or select the User Code slot you wish to delete. You will enter the
User
Code Edit Select
menu.
3. Press [
] to delete both the user code and the proximity tag.
NOTE: User code can only be deleted individually.
NOTE: User 40 - Master Code cannot be deleted; a deletion attempt
on this user code will delete the proximity tag only.
NOTE: A user code, once deleted, must be re-enrolled before it can
be used again.
[1] - A, B, C, 1 [4] - J, K, L, 4 [7] - S, T, U, 7 [0] - Space
[2] - D, E, F, 2 [5] - M, N, O, 5 [8] - V, W, X, 8
[3] - G, H, I, 3 [6] - P, Q, R, 6 [9] - Y, Z, 9,0
Symbol Description
Ready Light (green)
If the Ready light is on, the system is ready for
arming.
Armed Light (red)
If the Armed light is on, the system has been
armed successfully.
System Trouble (yellow) Indicates that a system trouble is active.
AC (green) Indicates that AC is present at the keypad.
The complete R&TTE Declaration of Conformity can be found at
http://www.dsc.com/listings_index.aspx.
The WT5500 Wire-Free Keypad is designed to work with the PC9155 Wire-
less Panel. Since the PC9155 is mounted in a secure location within the
home, the WT5500 is the main interface to the system.
Specifications
Unpacking
The WT5500 keypad package is available in five distinct configurations,
Wall mount, Wall mount w/Proximity, Desk Stand, Accessory Kit and Proxim-
ity Tags Only. The contents of each are described below.
Mounting
You should mount the keypad where it is accessible from designated points
of entry and exit. Once you have selected a dry and secure location, perform
the following steps to mount the keypad.
Wall Mounting Plate
1. Locate the screw holes (4) at each corner of the mounting plate.
2. Use the four screws provided to affix the mounting plate to the wall, ensure
the mounting tabs are facing you (see above diagram).
3. Align the four mounting slots in the WT5500 housing with the four mount-
ing tabs protruding from the mounting plate.
4. Slide the keypad into place.
5. Firmly but carefully snap the keypad down onto the mounting plate.
6. To fasten the keypad more securely onto the mounting plate, locate the
two screw holes in the bottom of the mounting plate then using the two
screws provided in the hardware pack, screw the keypad into place.
Desk Stand - WT5500D
1. Insert the four rubber feet
(found in the hardware pack)
into the indentations provided
in the bottom of the desk stand.
2. Place the desk stand on a
secure, uncluttered surface.
3. Align the four mounting slots in the WT5500 housing with the four mount-
ing tabs protruding from the desk stand.
4. Slide the keypad into place. Firmly but carefully snap the keypad down
onto the desk stand.
5. To fasten the keypad securely onto the desk stand, locate the two holes in
the top corners of the back of the desk stand, then using the two screws
provided screw the keypad to the desk stand.
Apply Battery Power
1. Slide the keypad up and out from the mounting plate/desk stand (remov-
ing the screws first if required). The bay for the four AA batteries is open
and visible at the back of the keypad.
2. Insert the batteries as directed on the back of the keypad. Ensure the cor-
rect polarity is observed.
3. Replace the keypad on the mounting plate / desk stand.
Apply AC Power
1. Slide the keypad up and out from the mounting plate / desk stand.
2. Locate the power adaptor jack at the back of the keypad housing.
3. Place the adaptor plug in the housing indentation, perpendicular to the
keypad. Insert the adaptor plug firmly into the jack.
4. Pivot the adaptor plug downwards so that it fits flush with the housing.
Guide the AC wire along the channel provided in the keypad housing; the
wire will finally extend through the bottom of the housing.
5. Replace the keypad on the mounting plate/desk stand (in the latter case, a
further channel is provided in the bottom of the desk stand. Guide the AC
wire along this channel; the wire will finally extend through an opening in
the back of the stand).
6. Plug the adaptor into a wall outlet.
NOTE: Only use the power adaptor (4.5VDC, 0.5A, 2.25W) supplied
with the kit.
CAUTION: The socket-outlet in which the direct plug-in adaptor is
inserted, must be close to the keypad and easily accessible. The
plug of the adaptor serves as a means of disconnection from the
supply mains.
Programming the Keypad
T
here are several programming options available for the keypad (see below).
Programming the keypad is similar to programming the rest of the system. To
turn an option on/off, press the number corresponding to the option on the
number pad. The numbers of the options that are currently turned on will be
displayed along the top of the LCD. For information on programming the rest
of your security system, please refer to your system’s Installation Manual. A
maximum of four keypads can be on the system at any one time.
Language Programming
Hold the (<>) keys for 2 seconds to enter language programming. Scroll
to the desired language and press [] to select.
If Section 075, Option 4 is turned off, language programming can
only be performed while in installers programming.
Installation Instructions
Temperature range: -10°C to +55°C (14°F to 131°F), Temperature range for
UL/ULC: 0°C to +49°C (32°F to 120°F)
Humidity (MAX): 93%R.H.
Plastic enclosure protection degree: IP30, IK04
Power Adaptor Output Voltage: 4.5VDC @ 0.5A
Models - US/Latin America: SA103A-0506-6U; Canada: SA103A-0506-6; EU:
SA103A-0506G-6; UK: SA106C-05BS; AUS./NZ: SA106C-05AS;
China: SA106C-05HS.
Battery: 4 AA, 3V, Energizer Alkaline
WT5500 Current draw: 50mA
Wall-mount tamper
5 programmable function keys
Ready (Green LED), Armed (Red LED), Trouble (Yellow LED), AC (Green LED)
Frequency: 433.92MHz (WT5500-433/WT5500P-433 only)
Frequency: 868.35MHz (WT5500-868/WT5500P-868 only)
WT5500 - WALL MOUNT WT5500DMK - ACCESSORY KIT
• 1 WT5500 Keypad • 1 WT5500DMK Keypad
• 1 WT5500BRK Wall Bracket • 1 Hardware Pack
• 1 Installation Manual • 1 Power Adaptor
• 1 Inner Door Sticker
• 4 AA Batteries
WT5500P - WALL MOUNT/PROX TAG
• 1 Hardware Pack • 1 WT5500P Keypad
• 1 WT5500BRK Wall Bracket
WT5500D - DESK STAND • 1 Installation Manual
• 1 WT5500 Keypad • 1 Inner Door Sticker
• 1 WT5500DMK Desk Stand • 4 AA Batteries
• 1 WT5500BRK Wall Bracket • 1 Hardware Pack
• 1 Installation Manual
• 1 PT4 or PT8 Prox Tag (433MHz/868MHz)
• 1 Inner Door Sticker
• 1 Power Adaptor PROXIMITY TAGS ONLY
• 4 AA Batteries
• 1 PT4 or PT8 Prox Tag (433MHz/868MHz)
• 2 Hardware Packs • 1 Installation Manual
Mounting
Tabs
DG009049
Screw
Holes
Screw
Holes
Screw
Holes
Screw
Holes
DG009096
$$
$$
$$
$$
DG009048
Mounting
Holes
Mounting
Holes
Batteries
Plug
Wire
Channel
Tamper
Switch
NOTES:
System is
Ready to Arm
<>
DG009153
Prox Tag
Reader
Page view 0
1 2

Summary of Contents

Page 1 - Ready to Arm

EnglishWAR NING: Please refer to the System Installation Manual for information on limitations regarding product use and function, and information on

Page 2 - Keypad Programming

Keypad Function Key ProgrammingEnter keypad programming by pressing [4][8][Installer Code][4][000]. Press 1 through 5 for individual function key pro

Comments to this Manuals

No comments