4 Programming
4-1
4 Programming
The PC9155 can be programmed using the following methods:
4.1 Template Programming
Template Programming allows the installer to quickly program the minimum functions required for basic operation. The installer is prompted to
enter a 4-digit code that selects predefined zone definitions, reporting code formats, troubles and restorals, and DLS setup (see the tables for digits
1 - 4 below). The installer is then prompted to enter the central station telephone number and account code, DLS access code, entry and exit
delays and a new installer code.
Perform the following after completing the hardware installation. Ensure you have the information listed below available for programming.
Record this information in section 5.2 Programming Worksheets for future reference:
Monitoring Station Telephone Number - Provided by your alarm monitoring service.
Monitoring Station Account Code - Provided by your alarm monitoring service.
Downloading Access Code.
Entry Delay - Installer defined.
Exit Delay - Installer defined.
Installer Code - User defined unique 4-digit code. The default value is [5555].
To perform template programming:
1. At the “Ready to Arm” screen, enter [
][8][5555][899].
2. At the “Enter Data” screen, enter [0001] to accept the existing default programming. See the tables below for details of digits 1-4.
3. After entering [0001], the first telephone entry is displayed. Enter the monitoring station telephone number after the “D”. DO NOT delete
any of the remaining F’s. Press [#] to complete the entry.
4. After programming the first telephone number, the system account code is displayed.
The system account code can be any 6-digit combination of numbers (0-9) and letters (A-F). If the system account code is 4-digits, the
last two digits must be “FF”.
To enter the letters A through F, press [
] then the numbers 1 through 6 for the letter A through F respectively. Press [ ] again to revert
back to decimal entry. E.g., to enter “1234FF” press [1234*66].
See section [310] for additional details.
5. After programming the system account code, the downloading access code is displayed. Enter the new downloading access code or press [#]
to proceed to the next step. See section [403] for additional details.
6. The entry delay is the amount of time given to disarm the alarm system, after entering the premises through a delay type zone, before an
alarm is sounded. Press [>][>][>] to accept the default time of 30 seconds (030) or enter an entry delay between 001 and 255. E.g., Press 020
for a delay of 20 seconds. See section [005] for additional details.
7. The exit delay is the amount of time given to exit the premises after pressing the Arm key before the alarm system is armed. Press [>][>][>]
to accept the default time of 120 seconds (120) or enter an entry delay between 001 and 255. E.g., press 030 for a delay of 30 seconds. See
section [005] for additional details.
8. After programming the exit delay, the installer code is displayed. Enter a 4 or 6-digit code depending on the value in section [701] option 5.
9. Press [#] to exit Template Programming. See section [006] for installer code details.
Programming Method Description Procedure
Template Programming Allows the minimum required data to be programmed. It
also allows for the setup of DLS downloading software.
Press [899] at the “Enter Section” screen.
See Template Programming below for details.
DLS Programming Allows programming to be downloaded using DLS-IV®™
software.
DLS programming can be performed locally with a PC-
Link cable and a PC with DLS-IV software installed.
DLS programming can be performed remotely via tele-
phone line, GPRS network or the Internet.
DLS Programming can be set up from Template
Programming (See Steps 3, 4 and 5) or from
Installer Programming (See programming sections
[401]-[499]).
Installer Programming Allows direct access to all programming sections. Template
programming is accessed from here.
Press [
][8][Installer Code] while the system is
disarmed.
Refer to Installer Programming in section 4.3 for
details.
Page view 16
1 2 ... 12 13 14 15 16 17 18 19 20 21 22 ... 79 80

Comments to this Manuals

No comments