Alexor PC9155G-868 Installation Guide Page 18

  • Download
  • Add to my manuals
  • Print
  • Page
    / 80
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 17
PC9155 Wireless Alarm System
4-2
Digit 1 selects one of the following zone definition options for the first 8 zones. A “0” in the digit 1 location indicates that the default settings
for the first 8 zones are in place unless overridden during enrollment. See section [001] for defaults.
Digit 2 selects one of the following reporting code options:
Digit 3 selects one of the following options:
Digit 3 - Table Headings/Descriptions
Option Zn1 Zn2 Zn3 Zn4 Zn5 Zn6 Zn7 Zn8 Zone Definitions (Options 1- 7)
0 This entry will not change the currently programmed zone definitions.
1 01 03 03 03 04 04 04 04 01 Delay 1
2 01 03 03 05 05 05 05 88 02 Delay 2
3 01 03 03 05 05 05 05 87 03 Instant
4 01 01 03 03 03 03 03 03 04 Interior
5 01 03 03 06 05 05 05 05 05 Interior Stay/Away
6 01 03 03 06 05 05 05 88 06 Delayed Stay/Away
7 01 01 06 06 06 01 01 01 87 Delayed 24 Hr.
Refer to Chapter 5 for zone definition details. 88 Standard 24 Hr. Fire
Opt# Phone Line 1 Programming Section Phone Line 3 Programming Section
0 This entry will not change the existing communications programming.
1 Disabled [380] Opt 1 OFF Disabled
2 SIA Automatic Reporting Codes Enabled [350] 1st Phone # [04]
[380] Opt 1 ON
[381] Opt 3 OFF
SIA Automatic Reporting Codes
Enabled
[350] 3rd Phone # [04]
3 Contact ID Automatic Reporting Codes Enabled [350] 1st Phone # [03]
[380] Opt 1 ON
[381] Opt 7 OFF
SIA Automatic Reporting Codes
Enabled
[350] 3rd Phone # [04]
[381] Opt [03] OFF
4 SIA Automatic Reporting Codes Enabled [350] 1st Phone #[04]
[380] Opt 1 ON
[381] Opt 3 OFF
Residential Dial
Enabled
[350] 3rd Phone # [06]
5 Contact ID Automatic Reporting Codes Enabled [350] 1st Phone # [03]
[380] Opt 1 ON
[381] Opt 7 OFF
Residential Dial
Enabled
[350] 3rd Phone # [06]
6 Contact ID Automatic Reporting Codes Enabled [350] 1st Phone # [03]
[380] Opt 1 ON
[381] Opt 7 OFF
Contact ID Reporting Codes
Enabled
[350] 3rd Phone # [03]
Option
Common
Group
Selected
Troubles
Openings/
Closings
Zone
Restorals
DLS/Installer
Lead In/Out
0 This entry will not change the existing call direction programming.
1

2

3

4

5

6

7

8
indicates included, Blank indicates default setting, indicates disabled
Common Group - Sets all Reporting Codes to Automatic Selected Troubles
Description Phone
#1
Phone
#3
Sections Trouble [345]
Alarms
[346]
Restoral
Set all reporting codes to automatic [320] - [348] FF Battery FF FF
Alarm/restore call directions enabled [351][1] ON, [351][2-4] No Change AC Failure 00 00
Tamper/restore call directions disabled [359][1] OFF, [1-4] OFF Fire Trouble FF FF
Opening/closing call directions disabled [367][1] OFF, [1-4] OFF Aux PS FF FF
Maintenance call directions enabled [375][1] ON, [351][2-4] No Change TLM XX 00
General System
Tro uble
00 00